1.
Health Secur ; 20(2): 154-163, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35467945

RESUMO

We conducted a comprehensive, multiphase laboratory evaluation of InBios Active Melioidosis Detect (AMD) rapid test, a lateral flow immunoassay designed to detect capsular polysaccharides produced by Burkholderia mallei or Burkholderia pseudomallei, used in conjunction with the Omni Array Reader (OAR) for the rapid detection of B mallei or B pseudomallei in environmental (nonclinical) samples at 2 sites. The limit of detection, using reference strains B mallei strain ATCC 23344 and B pseudomallei strain ATCC 11668, was determined to be 103 to 104 CFU/mL. In different phases of the evaluation, inclusivity strains that included geographically diverse strains of B mallei (N = 13) and B pseudomallei (N = 22), geographically diverse phylogenetic near neighbor strains (N = 66), environmental background strains (N = 64), white powder samples (N = 26), and environmental filter extracts (N = 1 pooled sample from 10 filter extracts) were also tested. A total of 1,753 tests were performed, which included positive and negative controls. Visual and OAR results showed that the AMD test detected 92.3% of B mallei and 95.5% of B pseudomallei strains. Of the 66 near-neighbor strains tested, cross-reactivity was observed with only B stabilis 2008724195 and B thailandensis 2003015869. Overall, the specificity and sensitivity were 98.8% and 98.7%, respectively. The results of this evaluation support the use of the AMD test as a rapid, qualitative assay for the presumptive detection of B mallei and B pseudomallei in suspicious environmental samples such as white powders and aerosol samples by first responders and laboratory personnel.


Assuntos
Burkholderia mallei , Burkholderia pseudomallei , Melioidose , Humanos , Melioidose/diagnóstico , Filogenia , Extratos Vegetais
2.
Health Secur ; 20(2): 164-171, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35467946

RESUMO

We conducted a comprehensive, multiphase laboratory evaluation of the InBios Active Melioidosis Detect (AMD) rapid test, a lateral flow immunoassay designed to detect capsular polysaccharides produced by Burkholderia mallei or Burkholderia pseudomallei, used in conjunction with the Omni Array Reader for the rapid identification of culture isolates of B mallei or B pseudomallei to support clinical diagnosis for response and triage during a mass casualty event, such as a biological attack. The study was conducted at 2 sites to assess the performance of the AMD test. The sensitivity, specificity, and reproducibility of the assay was determined using 5 replicates of 35 inclusivity strains and 64 clinical background strains. A total of 520 tests were performed, which included both positive and negative controls. Results obtained visually and with the Omni Array Reader showed a sensitivity of 92.3% for B mallei and 95.6% for B pseudomallei; no cross-reactivity was observed with any of the 64 clinical background organisms. The results from this study indicate that the AMD test for the presumptive identification of B mallei and B pseudomallei isolates to support clinical diagnosis is highly robust, specific, and sensitive. This evaluation supports the use of this test as a rapid, qualitative assay for the presumptive identification of B mallei and B pseudomallei in a clinical setting.


Assuntos
Burkholderia mallei , Burkholderia pseudomallei , Melioidose , Humanos , Melioidose/diagnóstico , Reprodutibilidade dos Testes
3.
Health Secur ; 17(4): 334-343, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31433282

RESUMO

A comprehensive laboratory evaluation of the Tetracore RedLine Alert test, a lateral flow immunoassay (LFA) for the rapid presumptive identification of Bacillus anthracis, was conducted at 2 different test sites. The study evaluated the sensitivity of this assay using 16 diverse strains of B. anthracis grown on sheep blood agar (SBA) plates. In addition, 83 clinically relevant microorganisms were tested to assess the specificity of the RedLine Alert test. The results indicated that the RedLine Alert test for the presumptive identification of B. anthracis is highly robust, specific, and sensitive. RedLine Alert is a rapid test that has applicability for use in a clinical setting for ruling-in or ruling-out nonhemolytic colonies of Bacillus spp. grown on SBA medium as presumptive isolates of B. anthracis.


Assuntos
Antraz , Bacillus anthracis/isolamento & purificação , Testes Diagnósticos de Rotina , Imunoensaio , Animais , Antraz/diagnóstico , Antraz/microbiologia , Humanos , Sensibilidade e Especificidade , Ovinos